Item |
Des cription |
ComPac® I and II (AVPxx AC) |
|||||||
20 |
24 |
30 |
36 |
42 |
48 |
60 |
72 |
||
1 |
Compres s or (Comp) ACA (1 Ph, 230 V) ACA (1 Ph, 230 V, Optional Sc roll) ACC (3 Ph, 230 V) ACC (3 Ph, 230 V, Optional Sc roll) ACD (3 Ph, 460 V) ACD (3 Ph, 460 V, Optional Sc roll) |
10046 n/a n/a n/a n/a n/a |
10205 10104 10206 10116 10207 10114 |
10208 10109 10209 10118 10211 10117 |
10233 10079 10226 10092 10227 10091 |
10052 n/a 10093 n/a 10094 n/a |
10202 n/a 10203 n/a 10204 n/a |
10108 n/a 10140 n/a 10120 n/a |
P/10005 n/a 10178 n/a 10179 n/a |
2 |
Compres s or Capacitor, ACA |
50265 |
50265 |
50280 |
50315 |
50322 |
50294 |
50159 |
50159 |
Compres s or Capacitor, ACA, (Scroll) |
n/a |
50280 |
50321 |
50310 |
n/a |
n/a |
n/a |
n/a |
|
3 |
Compres s or Contactor (CC) ACA (1 Phase) ACC, ACD (3 Phase) |
50010 n/a |
50010 50040 |
50010 50040 |
50020 50040 |
50020 50040 |
50020 50040 |
50030 50040 |
50030 50040 |
4 |
Condenser Coil |
60208 |
60208 |
60375 |
60375 |
60350 |
60345 |
60345 |
60007 (2) |
5 |
Outdoor Fan Motor (OFM) Standard |
40031 |
40031 |
40096 |
40096 |
40098 |
40098 |
40098 |
40051 |
Outdoor Fan Motor (OFM) Extrem e Duty |
40054 |
40054 |
40054 |
40054 |
40051 |
40051 |
40051 |
40051 |
|
6 |
Outdoor Motor Capac itor (OFMC) |
50350 |
50350 |
50350 |
50350 |
50240 |
50240 |
50240 |
50360 |
7 |
Fan Blade |
30110 |
30110 |
30115 |
30115 |
30135 |
30135 |
30135 |
30149 |
8 |
Evaporator Coil |
60207 |
60207 |
60385 |
60385 |
60360 |
60340 |
60061 |
60027 |
9 |
Indoor Motor (IBM) |
40045 |
40045 |
40055 |
40055 |
40099 |
40099 |
40046 |
40046 |
10 |
Indoor Motor Capacitor (IBMC) |
50350 |
50350 |
50350 |
50350 |
50360 |
50360 |
50360 |
50360 |
11 |
Indoor Blower - Left Hand |
30060 |
30060 |
30050 |
30050 |
30090 |
30090 |
30012 |
30025 |
12 |
Indoor Blower - Right Hand |
30065 |
30065 |
30055 |
30055 |
30092 |
30092 |
30013 |
30024 |
13a |
Capillary Tube |
80868 |
80869 |
80865 |
80866 |
80903 |
80660 |
n/a |
n/a |
Quantity Needed |
3 |
3 |
2 |
2 |
2 |
4 |
n/a |
n/a |
|
13b |
Dis tributor - Indoor (for Cap Tubes) |
80042 |
20294 |
20295 |
20295 |
80042 |
80042 |
n/a |
n/a |
13c |
Orific e - Cooling |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
20078 (.088) |
20239 (.094) |
13d |
Dis tributor - Indoor (Chatleff) |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
20033 |
20239 |
14 |
Heating Element (EH) |
SEE HEATING ELEMENT AND RELAY CHART BELOW |
|||||||
15 |
Dual Limit Control |
SEE HEATING ELEMENT AND RELAY CHART BELOW |
|||||||
16 |
Limit Control, Automatic Reset |
70005 |
70005 |
70005 |
70005 |
70005 |
70005 |
70005 |
70005 |
17 |
Heater Contac tor/Relay |
SEE HEATING ELEMENT AND RELAY CHART BELOW |
|||||||
18 |
Fuse Link (FL) |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
n/a |
19 |
Control Trans former, 40 va (Tran) |
50141 |
50141 |
50141 |
50141 |
50141 |
50141 |
50141 |
50141 |
20 |
Trans former (ACD Only) |
n/a |
50146 |
50146 |
50146 |
50147 |
50147 |
P/50007 |
P/50008 |
21 |
Blower Time Delay Relay (BTR) |
50419 |
50419 |
50419 |
50419 |
50419 |
50419 |
50419 |
50419 |
22 |
Lockout Relay (LOR) |
50214 |
50214 |
50214 |
50214 |
50214 |
50214 |
50214 |
50214 |
|
|||||||||
|